Guangdong Zhuhai Testing Institute developed wireless wire rope leakage magnetic detector

<

[ Instrument Network Instrument Development ] Wire rope is a flexible member widely used in engineering. In use, wire ropes are often a key component of the equipment, even "life roots." In order to ensure the safe, reliable and efficient operation of the wire rope, it is necessary to test the running condition of the wire rope, such as broken wire, abrasion, rust defects, fatigue, residual load capacity and safety factor.
The traditional wire rope testing method is a manual visual inspection. This method is used by a full-time inspector to observe the wire rope in use at regular intervals, and the caliper is used to measure the rope diameter, hand touch or naked eye to find defects. Obviously, manual visual inspection can only find defects exposed in the wire rope, such as (broken wire), and there is no power for internal defects. Wire ropes or wire rope segments that are invisible to the human eye will not be inspected and will be affected by human factors. Larger, the reliability of the inspection results is poor.
Recently, Zhuhai Testing Institute successfully developed a wireless wire rope magnetic flux leakage detector. Based on the research and development of wireless wire rope magnetic flux leakage detector based on TMR array double detection ring, the project has applied for 2 invention patents and authorized utility model patents. 2 pieces, obtained 1 software copyright, published 2 papers (including 1 EI search), compiled 1 product standard, and owned independent intellectual property rights.
This project is aimed at the problem of wire rope detection technology, and proposes a double-loop detection integrated method of active excitation and residual magnetic leakage magnetic field to effectively reduce the false positive rate of wire rope defect detection. The multi-sensor detection scheme suitable for wire rope set is designed to optimize the sensor magnetic field. Road structure and magnetic sensor layout, with multiple wire rope synchronous magnetic flux scanning imaging function; developed wireless wire rope group magnetic flux leakage detector, can achieve slight wear, single broken wire and other defects detection, can be widely used in inspection Inspection and inspection and daily maintenance of the inspection organization and elevator installation maintenance unit can effectively improve the detection rate and discovery rate of wire rope defects, eliminate the safety hazards in the bud, and have good social benefits. The identification results have reached the international advanced level. .

Industrial Fan

Product Profile Large energy saving ceiling fans are green energy saving products of the 21st century. It has many advantages, such as powerful, no noise, zero pollution, low energy consumption. It is very popular for large masses of users. It is not only mainly used in steel structure plant, logistics warehouse, farm and other large enterprise buildings, but also agricultural markets, gymnasiums, waiting rooms, exhibition halls and other large public buildings. A large energy-saving ceiling fans with a speed of 50 revolutions per minute 1 to 3 meters per second to make the human body feels the best wind speed. A breeze from all directions gently caresses the body and increases the evaporation of human sweat. The cooling effect of 5 to 8 degrees is similar to the comfort presented by the natural breeze, which can not be matched by other fans. It is an ideal choice for indoor, ventilation and cooling in summer to remove humidity and heat. Only seven degrees of electricity per day, it can be cool for a whole summer. Energy saving comparation In summer, the sun shines directly and the indoor temperature is more than 40 degrees on average. Common industrial exhaust fans can only increase the indoor temperature. Industrial air conditioners consume thousands of kilowatts of energy every shift. There is no obvious unenclosed cooling in the space, which also increases the operating cost of enterprises. The emergence of a large energy saving ceiling fan brought the perfect solution. An energy saving fan with a diameter of 7.2meters can push the air to produce a large amount of winds effectively. The continuously rotating blades of circular form an airflow field with an effective area of 600 to 800 square meters. No other device has not yet been compared. The large energy-saving ceiling fan praduced by Linter technology has the characteristics of high reliability, feasibility and low power consumption. The controller unit used the stability of the energy-saving inverter system. In practice, the average power consumption is less than one killowatt per hour. It can guarantee more than 5,000 hours of uninterrupted operation. Linter7200 of a large energy-saving ceiling fan can cover the area of about 50 small fans of 0.75 megabytes worked. In a factory of 9000 square meters, if full coverage is to be achieved, it needs about 300 small fans or industrial 6 energy-saving fans. According to the use of four years, every eight months, every day for ten hours, can be run for 10,000 hours, about 90000kw power consumption, than the small wind 1080000kw, save 990000kw, save energy by 92%. When meeting the extreme high temperature climate, the large energy saving fans and air conditioners are used together, it will be coller. Using A large energy-saving ceiling fan for air supply can not only save the air conditioning tube, but also save more than 30% energy. Attentio Lectotype The building structure: H-shaped steel, I-shaped steel, Mixed steel square bar spherical column spherical structure. The total height of the building is more than 4, 0m, less than 15m. 1, 0m. The minimum distance between the fan and the roof is 1, 0m. The minimum safety distance between the fan blades and the obstacle is 0, 3 m. The distance between the fan blades and the wall on both sides is more than 1, 5 m. Effects of various environments on fan performance. Open space, promotes air circulation. Indoor airflow circulation in enclosed spaces is suitable for use with air conditioning. In a multi-fan environment, due to the low wind speed, caused by the fan, there will be no cyclones. The distance between the two fans will be separated before the wind will not cancel, and the coverage area will be increased at the same time. Company Information HongFa automatic door Technology (Shenzhen) Co., Ltd is a high-tech enterprise which engages in the development of advanced world-class automatic doors. Our main products include industrial fast rolling door, industrial PVC rolling door, industrial PVC rolling door, fast rolling door, rolling door, fast rolling door, rolling door, industrial automatic lifting door, industrial automatic lifting door, automatic vertical hinged door, automatic stainless steel door, automatic doors, automatic doors, electric folding gate, rolling door, automatic doors, automatic doors, automatic doors, automatic doors,

Industrial ceiling fan,electric fan,industrial fan

SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfahss.com